Rotary Geared Limit Switch
Providing the best construction policy to customers.
Labh Engineering
FLP Rotary limit switch 40 AMPS
Technical Characteristics:
- Rating: Max Current 40 Amps At 415 V.a.c 50 C/s
- Gear Ratio: 48:1 Or 88:1,permissble Nos. Of Revolution 40 Or 80
- Nos. Of Contacts: 4 Nos. (2 Nc Or 4 Nc)
- Max. Switching Frequency : 1000 Per Hr
- Construction : In Aluminium Alloy Lm6
- Gas Group :iia/iib/iic As Per Is/iec 60079-1:2014,ex "D",epl Gb & Db Atmosphere
- Zone : Zone 1 & 2
- Deg. Of .prot. : Ip:66 As Per Is/iec 60529-2001(Reformed 2014)
- Dust Ignition Prot. : As Per 't' Is/iec 60079-31:2013
- Temp. Class : T6
- Peso Cert. No. : A/p/hq/mh/104/7559 (P559440/5) Dtd. 10/04/2023
- Cimfr Cert. No. : In/cimfr/tr20/h293 Dtd. 25/02/2020
- Bis Cert. No. : Cm/l-7800028013 Dtd. 27/09/2017
- Paint : Epoxy Smoke Grey
Labh Engineering
Flp Lever ls 40 Amps
Technical Characteristics:
- Rating: Max Current 40 Amps At 415 V.a.c 50 C/s
- Max Nos. Of Contacts: 2 Nos. (2 Nc Or 1 No + 1nc)
- Max. Switching Frequency : 1000 Per Hr
- Construction : In Aluminium Alloy Lm6
- Gas Group : Iia/iib/iic As Per Is/iec 60079-1:2014,ex "D",epl Gb & Db Atmosphere
- Zone : Zone 1 & 2
- Deg. Of .prot. : Ip:66 As Per Is/iec 60529-2001(Reformed 2014)
- Dust Ignition Prot. : As Per 't' Is/iec 60079-31:2013
- Temp. Class : T6
- Peso Cert. No. : A/p/hq/mh/104/7559 (P559440/6) Dtd. 10/04/2023
- Cimfr Cert. No. : In/cimfr/tr20/h293 Dtd. 25/02/2020
- Bis Cert. No. : Cm/l-7800028013 Dtd. 27/09/2016
- Paint : Epoxy Smoke Grey